This drawing shows the receptacle engaging face; the plug would have the reverse (clockwise) from the master keyway. In the normal position (N) the centerline of the insert is the same as the master keyway of the shell. In the alternate positions ( 6, 7, 8, 9, and Y) the minor keyways are positioned counter clockwise when looking at the receptacle face. The degree of change is shown in the tables.
CLOCKING POSITION |
SHELL SIZE 8 | |||
A | B | C | D | |
NORMAL | 105 | 140 | 215 | 265 |
6 | 102 | 132 | 248 | 320 |
7 | 80 | 118 | 230 | 312 |
8 | 35 | 140 | 205 | 275 |
9 | 64 | 155 | 234 | 304 |
Y | - | - | - | - |
CLOCKING POSITION |
SHELL SIZE 10 | |||
A | B | C | D | |
NORMAL | 105 | 140 | 215 | 265 |
6 | 102 | 132 | 248 | 320 |
7 | 80 | 118 | 230 | 312 |
8 | 35 | 140 | 205 | 275 |
9 | 64 | 155 | 234 | 304 |
Y | 25 | 115 | 220 | 270 |
CLOCKING POSITION |
SHELL SIZE 12 THRU 24 | |||
A | B | C | D | |
NORMAL | 105 | 140 | 215 | 265 |
6 | 18 | 149 | 192 | 259 |
7 | 92 | 152 | 222 | 342 |
8 | 84 | 152 | 204 | 334 |
9 | 24 | 135 | 189 | 240 |
Y | 98 | 152 | 268 | 338 |